Switchboards,
Links to
Overview | Standard Enclosure Dimensions | Products | Main Switches | Features |
||||||||||||||||||||||||||||||||||||||||||||||||
| Switchboards
(Products) Power and Distribution |
||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||
| CDP-6 250 VOLTS DC MAXIMUM 600 VOLTS AC MAXIMUM 1200 AMPERE MAXIMUM MAINS UL SHORT CIRCUIT RATING - 200,000A IR MAXIMUM |
VB-6 250 VOLTS DC MAXIMUM 600 VOLTS AC MAXIMUM 600 AMPERE MAXIMUM BRANCH UL SHORT CIRCUIT RATING - 200,000A IR MAXIMUM |
|||||||||||||||||||||||||||||||||||||||||||||||
| Meets
1984 wire bending requirements, section 373-6 SWITCHBOARDS: Listed by Underwriters' Laboratories, Inc., under File #32546. Meet Federal Specification W-P-115 dated June 8,1984, for Type I Class 1. SERVICE: 250 Volts DC, 600 Volts AC Maximum. 1 Phase, 3 Wire, 3 Phase, 3 Wire or 3 Phase, 4 Wire. STANDARD ENCLOSURE WIDTH is 34 inches. Enclosures are painted ANSI-61. Enclosure tops are field removable. Enclosure depth is 24". STANDARD IS WITHOUT DOOR. Doors are available on request. Enclosure floor depth increases to 18 inches. MOTOR STARTERS are available in CDP-6 switchboards. BRANCH BREAKERS: Interrupting Capacities based on UL test procedures at rated voltage. Meet Federal Specification W-C-375B dated July 22, 1975. |
Meets
1984 NEC wire bending requirement, section 373-6. SWITCHBOARDS: Listed
by Underwriters' Laboratories, Inc. under File #32546. Meet Federal Specification
W-P-115b dated June 8,1984, for Type II, Class 1. SERVICE: 250 Volts DC, 600 Volts AC Maximum. 1 Phase, 3 Wire, 3 Phase, 3 Wire; or 3 Phase, 4 Wire. STANDARD ENCLOSURE WIDTH is 34 inches. 30-inch wide enclosures are available on request when branch Vacu-break switches are 200A maximum. Enclosures are painted ANSI-61. Enclosure top is field removable. Enclosure depth is 24". STANDARD IS WITHOUT DOOR. Doors are available on request. Enclosure floor depth increases to 18 inches. MOTOR STARTERS: Available in switchboards. BRANCH SWITCHES: Vacu-Break horsepower-rated fusible switch units |
|||||||||||||||||||||||||||||||||||||||||||||||
| MAIN LUG PANEL CONNECTORS | ||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||
| VB-6 BRANCH SWITCHES | ||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Switchboards,
Links to
Overview | Standard Enclosure Dimensions | Products | Main Switches | Features |
||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||