Switchboards
(Main Switches)
Power and Distribution
|
 |
BASE
PRICE MAIN LUG & DISTRIBUTION SECTION SWITCHBOARDS
|
Amperage
|
3P4W
|
3P3W
|
1P3W
|
1P2W
|
CROSS
BUS
|
DIST
U
|
3P3W
U
|
3P4W
U
|
W
|
|
225
400
600
800
1200
1600
2000
|
Please
Call for Current Pricing:
(313)
366-2200
|
|
|
60
57.5
55
55
55
55
55
|
|
|
|
MAIN
SWITCHES VB STYLE
|
Amps
|
250
Volt
|
480
Volt
|
U
|
W
|
|
200
400
600
800
12001
|
Please
Call for Current Pricing:
(313)
366-2200
|
52.5
42.5
40
25
25
|
34
34
34
34
34
|
1 If
GFI required use bolted pressure switch
|
|
|
|
MAIN
SWITCHES BOLTED PRESSURE
|
Amps
|
250
Volt
|
480
Volt
|
U
|
W
|
D
|
|
800
|
Please
Call for
Current Pricing:
(313)
366-2200
|
25
|
34
|
24
|
|
1200
|
20
|
34
|
24
|
|
1600
|
20
|
34
|
24
|
|
2000
|
20
|
34
|
24
|
|
2500
|
20
|
42
|
24
|
|
3000
|
02
|
44
|
30
|
|
4000
|
20
|
44
|
30
|
|
|
| Switchboards
(Features) |
| Features |
|
|
The
Park Service Entrance Switchboard is a single unit system designed to meet
the needs of main overcurrent protection with distribution devices for medium
duty service applications. Main service disconnects can be either an I-T-E
Vacu-Breakš fusible switch or I-T-E circuit breaker. Each provides dependable
performance with series rated combinations available. All switchboards meet
EUSERC utility requirements, and are suitable for use only as service equipment.
|
A
|
NEMA
Type 1 indoor or Type 3R outdoor self-contained enclosures are constructed
of code gauge steel and painted ANSI-61 light gray. |
|
B
|
Rating
label information is clearly visible on the equipment front panel.
Metal nameplates are stamped and riveted to each switchboard for permanent
identification. Danger, short circuit rating labels and UL listing
label present necessary information to conform with NEMA Standard
PB-2. |
|
C
|
Incoming
main lugs are mechanical screw-type mounted on studs accepting a wide
range of cable sizes. These can be removed and replaced with compression
lugs supplied by the utility, if required. |
|
D
|
Barriered
hot sequence utility metering and fully bussed power company current
transformer compartment meet EUSERC utility standards. |
|
E
|
Service
disconnect can be fusible Vacu-Break switch through 200,000A IC or
circuit breaker with maximum rating of 50,000A IC at 240 volts and
35,000A IC at 480 volts. |
- High interrupting
capacity subfeed kits with molded case circuit breaker ratings
of 225 or 400 amperes
- Series rated
combinations are available. Consult sales oflice.
- Contact sales
oftice for delivery information.
|
|
|
Ampere
Ratings:
|
400-600-800
Ampere Circuit Breaker Main
400-600 Ampere Fusible Vacu-Break Main |
|
Voltage
Ratings:
|
| 120/240
Volts |
1
Phase, 3 Wire |
| 240 /120
Volts |
3
Phase, 4 Wire Delta |
| 240
Volts |
3
Phase, 3 Wire |
| 208Y/120
Volts |
3
Phase, 4 Wire |
| 480Y/277
Volts |
3
Phase, 4 Wire |
| 480
Volts |
3
Phase, 3 Wire |
|
I.C. Ratings: The short
circuit current rating is limited to the lowest current interrupting rating,
at the supply voltage, of any device installed. Only I-T-E breakers with
short circuit interrupting ratings equal to or greater than the marked short
circuit current rating shall be used for replacement or additions. |
|
|
|
|
| ©
Copyright Miller Media, Inc. 2000 |