PARK DETROIT
19197 Sherwood Ave.
Detroit, MI 48234
Tel: (313) 366-2200
Fax: (313) 366-1540

Busways, Links to:
Low and Medium Voltage
Non-Segregated Phase Type | Segregated Phase Type | Features | Construction Options
Pictures 
| Specifications PDF Format | Installation Manual PDF Format (Large File)

Low Voltage Collector Bus
  Open Enclosure Type | Features | Pictures | Specifications PDF Format

Low Voltage (BD Style)
Plug-In Duct Data
| Duct Sections | End Cable Tap Boxes | Flanged Ends and End Closers
Selecting Elbows Tees & Crosses



Low Voltage (Low Reactance / Impedance Style)
Low Reactance Plug In Bus Duct
Low Impedance
Feeder Duct | Short Circuit Ratings | Selecting Elbows Tees and Crosses

BusWays
End Cable Tap Boxes
     End Cable Tap Boxes are attached to either or both ends of a plug-in duct run. They are used for cable or conduit tap-off or feed-in. It is recommended that duct sections be installed with the offset bus-bar ends to the right. When so installed, standard End Cable Tap Boxes may be used and if desired the duct can be mounted against a wall or other flat surface. End Cable Tap Boxes always have straight bus-bar ends so that they can be connected to the offset ends of duct bus bars without the use of Adapter Straps and Covers. When End Cable Tap Boxes are connected to the straight ends of duct bus-bars, Adapter Straps and Covers must always be used. When the duct sections are installed with the offset bus-bar ends to the left and End Cable Tap Boxes are used, the duct cannot be mounted against a wall or other flat surface.
225 Ampere
Alum.
Capacity
Copper
1/2 Neut.
Full Neut.
A
B
C
D
E
F
400
-
600
800
800
-
400
600
-
800
800
1000

X
X
X
X

X
X
X

X
X

4 1/16"
4 1/16"
6 1/16"
6 1/16"
8 1/8"
8 1/8"

2"
2"
6"
6"
6"
6"
10"
10"
12"
12"
16"
16"
24"
24"
24"
24"
30"
30"

15"
15"
15"
15"
18"
18"

0"
0"
0"
0"
1"
1"
 
 
Copper Conductors
Aluminum Conductors
Duct Cap.
A
B
C
A
B
C
225 Amp
400 Amp
600 Amp
800 Amp
22"
22"
22"
22"

5"
5"
5"
5"

13"
13"
13"
14"

22"
22"
22"
22"

5"
5"
5"
5"
13"
13"
14"
15"
Connector (Lug) Data -400-1600 Amp
Pressure wire connector type
Capacity
Qty.
Alum
Copper
Per Pole
Wire Range
400
600
800
1000
400
600
800
1000

1
2
3
4

#4-600 MCM
#4-600 MCM
#4-600 MCM
#4-600 MCM

 

Busways, Links to:
Low and Medium Voltage
Non-Segregated Phase Type | Segregated Phase Type | Features | Construction Options
Pictures 
| Specifications PDF Format | Installation Manual PDF Format (Large File)

Low Voltage Collector Bus
  Open Enclosure Type | Features | Pictures | Specifications PDF Format

Low Voltage (BD Style)
Plug-In Duct Data
| Duct Sections | End Cable Tap Boxes | Flanged Ends and End Closers
Selecting Elbows Tees & Crosses



Low Voltage (Low Reactance / Impedance Style)
Low Reactance Plug In Bus Duct
Low Impedance
Feeder Duct | Short Circuit Ratings | Selecting Elbows Tees and Crosses

© Copyright Miller Media, Inc. 2000